Click on the appropriate buttons in the illustration.
Starter body
Terminal 50
Terminal C
Field coil lead wire
Terminal 30
Test lead A
Hold-in coil
Pull-in coil
Pinion gear
Check that the magnet starter switch
functions normally.
1.
Pull-in test
(1)
Disconnect the field coil lead wire from the terminal C to
prevent the starter from turning.
(2)
Connect the battery positive (+) terminal to terminal 50.
(3)
Connect the battery negative (-) terminal to the starter body and to the terminal C (test lead A), and check if the pinion gear extends to the engage position.
HINT:
•
The test reproduces a state of START position artificially. As current flow to the pull-in coil and hold-in coil and check that the pinion gear extends to the engage position.
•
If the pinion gear does not extend to the engage position, replace the magnet starter switch assembly.