Recover the refrigerant into the refrigerant recovery machine for reuse. |
 |
Immediately plug any disconnected part to prevent entry of moisture and dust |
 |
Do not leave a new condenser or receiver/dryer, etc, lying around with the plug removed. |
 |
Discharge the nitrogen gas from a new compressor via the charging valve before removing the plugs from the new compressor connections. If the nitrogen gas is not discharged via the charging valve first some of the compressor oil will spray out with the nitrogen gas when the plug is removed. |
 |
Do not bend or lengthen any of the pipes or tubes |